Skip to end of metadata
Go to start of metadata


Important Notes

Before you proceed with looking for a solution to your issue, double-check that your machine meets our system requirements.

For tips and common practices, refer to Tips and Tricks and Best Practices. If you still don't find your solution there, go to the community forum and escalate your issue.


Installation

The section describes how you can solve issues that may occur during Intelligent Automation Cloud – Express and Business – installation.

Error code 0x80070661

Valid up to version 2.1.0

Symptoms

SYMPTOMS
Installation failed with error code 0x80070661.

Resolution

RESOLUTION

  1. Your target machine has 32-bit operating system installed.
  2. Check that you have 64-bit operating system (32-bit is not supported).

Error code 0x80070643

Symptoms

SYMPTOMS

Installation failed with error code 0x80070643. This exception can have different causes, see several solutions below.

Resolution

RESOLUTION 1

  1. Some of .msi files can be moved to quarantine by anti-virus or anti-malware software.
  2. Disable your antivirus or anti-malware software temporarily, restore file, and run IntelligentAutomationCloudInstaller.exe once again.
  3. If this doesn't help, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.

Resolution

RESOLUTION 2

  1. Some of ports on your PC are blocked by your organization policy or firewall. You can find more information here — Express/Business Installation - Preconditions.
  2. Check with your local IT department and after fixing the issue, run IntelligentAutomationCloudInstaller.exe once again.
  3. If this doesn't help, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.

Resolution

RESOLUTION 3

  1. If you have a policy that prevents to install software on the C:\ drive, try to use another folder or another drive instead of default while installing. For example,
    1. C:\Test
    2. D:\IntelligentAutomationCloud
    3. C:\Program Files\IntelligentAutomationCloud (or alternatively C:\Program Files (x86)\IntelligentAutomationCloud depending on your system)
  2. Run IntelligentAutomationCloudInstaller.exe again and check the results.
  3. If this doesn't help, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.
Error code 0x80070570

Symptoms

SYMPTOMS

Installation failed with error code 0x80070570.

Resolution

RESOLUTION

  1. Make sure you have completely extracted the content of the installation archive (IntelligentAutomationCloudInstaller.zip) on your local drive.
  2. Disable your antivirus or anti-malware software.
  3. If this doesn't help, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.
Error code 0x80070005

Symptoms

SYMPTOMS

Installation failed with error code 0x80070005.

Resolution

RESOLUTION

In most cases it means that you don't have access to the folder C:\ProgramData\Package Cache. To check it, perform the following steps.

  1. Create a folder in C:\ProgramData\Package Cache, e.g., C:\ProgramData\Package Cache\test, then try to copy any file from your PC, and paste to this folder.
  2. If you get the message below, ask to obtain an appropriate permission from your local IT department in order to resolve the issue.

  3. If you are able to create folder in C:\ProgramData\Package Cache, but the issue still occurs, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.
Admin user update in PostgreSQL database failed

Symtomps

SYMPTOMS
The following window is being displayed during installation.

Resolution

RESOLUTION

  1. Check whether your system meets the system requirements.
  2. If it does, check with your local IT team whether port 15423 is blocked. In case it is blocked, ask to unblock it, and run the installation once again.
  3. If the port is not blocked and installation still fails with the same error, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.

Launch

The section describes how you can solve issues that may occur during launch of Express Edition or Business Edition.

Application shortcut doesn't start: pop-up window is showing

Valid up to version  2.1.5

Symptoms

SYMPTOMS
After clicking on the application shortcut, the following window is shown.

Resolution 1

RESOLUTION 1

  1. Right-click on the shortcut on your desktop.
  2. Press Change and find the application file wscript.exe in C:\Windows\System32 on your PC.
  3. Select this file, click Apply, and close shortcut properties.
  4. Run the application.

Resolution 2 (if Microsoft Windows Based Script Host is removed from PC)

RESOLUTION 2

  1. Open folder C:\RPAExpress\RPA\wfagent.
  2. Create a file with the name express.bat and add content as below.

    START /B ..\..\Applications\Java\bin\javaw -Dagent.showIntro=true -Dloader.path=lib -Dhttp.nonProxyHosts="localhost|127.0.0.1" -Djava.awt.headless=false  -Dagent.desktopType=RPA_EXPRESS -Dfile.encoding=UTF-8 -Xmx500m -jar status-agent.jar --spring.config.location=./express.yml


  3. Open the shortcut properties and change attributes as shown below.

  4. Launch the application.
Application shortcut doesn't start: Windows Script Host access is disabled

Valid up to version  2.1.5

Symptoms

SYMPTOMS

After clicking on the application shortcut, the following window is shown.

Resolution

RESOLUTION

If you don't have permissions to change registry, contact your IT department.

  1. Type regedit in the Run box and press Enter to open the Registry Editor.
  2. Navigate to the following key: HKEY_CURRENT_USER\Software\Microsoft\Windows Script Host\Settings
  3. On the right panel, Value name is Enabled. If you see the entry 0, the Windows Script Host access is disabled on your Windows machine. To enable, double-click it and set Value data to 1.

    1. A value of 1 enables Windows Script Host
    2. A value of 0 disables Windows Script Host
  4. Click OK and exit the Registry. 

If you don’t see this entry, go to HKEY_LOCAL_MACHINE\Software\Microsoft\Windows Script Host\Settings and repeat the steps above.

Platform Monitor page is unreachable

Valid up to version 2.3.0

Symptoms

SYMPTOMS

Connection to Platform Monitor via localhost cannot be established.

Resolution

RESOLUTION

Your computer is connected to the network via a proxy server, and the connection is managed by network administrators.

  1. Go to Control Panel > Internet Options and click LAN settings.
  2. Check if there is a proxy specified in Automatic configuration (it cannot be changed).
  3. Contact your network administrator and request to add the following resources to exceptions:
    • localhost
    • 127.0.0.1
Control Tower cannot be started

Valid up to version 2.3.0

Symptoms

SYMPTOMS

You tried to start Control Tower from the tray menu, but the status is Not started after several tries.

Mind that the tray menu is deprecated since RPA Express 2.3.0. Starting from 2.3.0, Control Tower is enabled on the Components tab in WorkFusion Studio.

Resolution

RESOLUTION

  1. Check whether your PC meets the system requirements. Note that Control Tower takes a lot of RAM, so you may need to close other active applications while Control Tower is starting.

    It can take up to 10-15 minutes, depending on the machine's properties, to start Control Tower.

  2. If your machine meets the system requirements, but Control Tower still hasn't started, try starting it using Platform Monitor.

    1. Open Platform Monitor from the tray menu. Mind that the tray menu is deprecated since RPA Express 2.3.0 as well.
    2. Go to System Processes and check components: 
      1. mysqld
      2. postgress
      3. tomcat
    3. They should have status stopped as on the screenshot below.
    4. Press Actions > Start for each of these components.
    5. In the window below, click OK and wait till the status of the components changes to running.

After that, you can log into Control Tower by opening this link in your browser: http://localhost:15280/workfusion/login

If the above steps are of no help, escalate on the community forum with a detailed description of your issue.

Bot Manager cannot be started

Valid up to version 2.3.0

Symptoms

SYMPTOMS

Bot Manager is stopped and cannot be started from the tray menu, while your machine is not connected to the network either by Ethernet or Wi-Fi.

Resolution

RESOLUTION

  1. Enable a Network interface.

    Important note

    It does not mean you should have access to Internet.

  2. Exit the application.
  3. Install Microsoft Loopback Adapter as described on Microsoft TechNet website or follow the instruction below (for Windows 10).
    1. Open My Computer > Properties.
    2. Open Device Manager.
    3. Go to Action and select Add legacy hardware.
    4. Click Next in Add Hardware Wizard.
    5. Choose Install the hardware that I manually select from a list (Advanced) and click Next.
    6. Select Network adapters in the hardware types and click Next.
    7. In the Select the device driver dialog, choose:
      1. Manufacturer – Microsoft
      2. Model – Microsoft KM-TEST Loopback Adapter

      and click Next.
    8. Click Next to install.
    9. Wait until the installation ends and click Finish to complete.
    10. Open Device Manager to make sure Lookback Adapter is installed and enabled.
  4. Wait until the connection is established.
  5. Open Command Prompt and use ipconfig to check the status of all network interfaces. Make sure Loopback Adapter has got the ip-addresses.
  6. Start the application.
  7. Check Bot Manager status in the tray menu.

    Mind that the tray menu is deprecated since RPA Express 2.3.0.

Components

The section describes how you can solve issues, that may occur while working with Express Edition or Business Edition.

Application does not respond

Symptoms

SYMPTOMS

Intelligent Automation Cloud – Express or Business – has got non-responsive and stays so for a long time.

Resolution

RESOLUTION

You should end all the processes manually.

For that purpose, we recommend to use Process Explorer (Windows Sysinternals tool), as the standard Windows Task Manager is not convenient to handle multiple processes.

  1. Go to Process Explorer page. There, you can find a description of the tool and the download link.
  2. Download Process Explorer and unpack it to a local folder on your computer.
  3. Start Process Explorer (procexp.exe or procexp64.exe) and accept EULA. Process Explorer opens.
  4. Find the following tasks:
    1. IntelligentAutomationCloud.Agent.exe with multiple sub-tasks (workfusion-studio.exe, java.exe, mysqld.exe, minio.exe, cmd.exe)

    2. cmd.exe with sub-tasks postgres.exe

  5. Select the task, right-click, and choose Kill Process Tree in the context menu.

  6. Do the same for the second task.

Components links are not opening in default browser

Symptomps

SYMPTOMS

Intelligent Automation Cloud Business looks launched successfully and doesn't show any warnings, but when clicking on links on the Components tab, nothing happens.

Resolution

RESOLUTION

  1. Check whether the following links are not working as well.
  2. If the links above are not working, change your default browser (for example, from Chrome to Firefox, or Internet Explorer) and check the links once again. 
  3. If the links work in another browser, check which extensions or plugins you have in your usual default browser. Try to switch them one by one and check how the links work. 
  4. When you found an extension that prevents to open the links, switch it off or configure to allow Intelligent Automation Cloud Business links to launch in the browser.
    Known case: Norton Safe Web extension for Chrome prevents to launch Business Edition links.
Server components are not found

Valid since version 2.3.0 

Symptoms

SYMPTOMS

After launching the application, you may see the message like below.

Resolution 1

RESOLUTION 1

  1. At first, check which installation type you have. If you installed Express Edition, it doesn't contain server components like Control Tower and File Storage. In this case, you won't be able to see these components on the Server Components tab.
  2. If you have Business Edition, make sure you have selected Development Workstation and Server option during installation.
  3. If you downloaded the right version and selected Development Workstation and Server, but the issue still persists, check your default server profile settings in Window > Preferences > WorkFusion Studio > Server Profiles. For non-server local installation, they should be like on the screenshot below. For more details about this window, see here.
  4. If the Preferences settings are correct, there are several scenarios to follow.
    1. Open Control Tower URL from the profile in browser. In case it shows the Control Tower login page, it means that your components work. Reopen WorkFusion Studio, it should show Components as usual.
    2. Close all unnecessary applications and exit Intelligent Automation Cloud Business. Make sure that it closes completely. Reboot your PC and launch Business Edition only, wait till it loads, and after that wait for 5-10 minutes for the components links to appear. 
  5. If it doesn't work, collect files from the folder C:\IntelligentAutomationCloud\Agent\Logs\ and WorkFusion Studio logs and escalate on the community forum.

Resolution 2

RESOLUTION 2

If Resolution 1 didn't help, close Intelligent Automation Cloud Business.

  1. Go to the folder C:\Users\<user_name>\.

  2. Find the folder named workfusion-workspace.

  3. Create the new folder with the name workfusion-workspace2 and copy all the files from the previous one.

  4. Start the application, wait for several minutes, and check the Components tab.

  5. If this doesn't help as well, collect and zip WorkFusion Studio log files as described here and escalate on the community forum with a short description of your issue.

Control Tower

No samples of business processes in Control Tower

Symptoms

SYMPTOMS

You see empty Business Processes list in Control Tower, though there should be samples with business processes.

Resolution

RESOLUTION

  1. Run your Control Tower if it is not started and open it.
  2. Go to the Business Processes list and click on the button next to Create New, and press Import package.
  3. Press Add in order to upload files.
  4. Find in the dialog window C:\Users\<user_name>\ControlTower\Samples. You should see several .zip archives and .csv files.
  5. Choose one of archives and press Open. You should see the following screen.
  6. Press Preview Package, wait a bit while the Import package button becomes available, and press it.

    After that, you can see sample business process in the list. 

Scheduled process doesn't appear in Business Processes list in Control Tower

Symptoms

SYMPTOMS 

When you set up schedule for some process it doesn't appear on the Business Processes tab.

Resolution

RESOLUTION

  1. Check that you have chosen the whole business process while scheduling, not a task.
  2. Correct the schedule for the whole business process, and you will see it in the list of all business processes.
Remote device or resource won't accept connection

Symptoms

SYMPTOMS

You cannot access Control Tower and WorkSpace. The message "The remote device or resource won't accept the connection" appears.

Resolution

RESOLUTION

This happens because of the use of proxy. Close your Intelligent Automation Cloud Express/Business completely and follow these steps.

  1. Press Win+R.
  2. Type in inetcpl.cpl.
  3. As soon as Internet properties open, switch to the Connections tab and select LAN settings.
  4. In the Local Area Network Settings window, uncheck the Use a proxy server for your LAN option. Automatically detect settings must be still checked though.
  5. Apply the changes.
Recording is playing in RPA Recorder but not in Control Tower

Symptoms

SYMPTOMS

You play the recording in WorkFusion Studio and it runs without errors. But after publishing the recording to Control Tower, it is not playing.

Resolution

RESOLUTION

If you use paths to files in your actions (Enter Keystrokes, Launch Application), make sure all backslashes are doubled, for example: C:\\Program Files\\Your Super Software\\Installer.msi

Script doesn't work after publishing to Control Tower

Symptoms

SYMPTOMS

Script is playing in WorkFusion Studio without errors. But after publishing it to Control Tower you see such exception in event log while running it:

Resolution

RESOLUTION

Make sure that you don't have a DateTime variable with a name start_date in your script. If you do, change the name of the variable to any other:

This variable name is used by Control Tower by default and it conflicts with your variable.

WorkFusion Studio

Unable to open recording

Symptoms

SYMPTOMS

While opening a recording created with a older version of Intelligent Automation Cloud – Express or Business, migration fails with the following error.

When you click OK, RPA Recorder cannot open the recording.

Resolution

RESOLUTION

Your recording is created with an older version of Intelligent Automation Cloud – Express or Business – and cannot migrate automatically due to changes in the action model.

  1. Close the tab that shows the error and close WorkFusion Studio.
  2. Go to your workspace folder (by default C:\Users\%username%\workfusion-workspace\rpae_project).
  3. Find the .rpae file you want to run.
  4. Open it with any text editor, e.g., Notepad.
  5. Find the string in the XML header which contains a wrong version number (see example below).

    xmlns:recorder="http://www.workfusion.com/recorder/v1.0.0"
  6. Change the namespace manually to the version of Express or Business Edition currently installed on your machine (for example, 2.4.0)

    xmlns:recorder="http://www.workfusion.com/recorder/v2.4.0"
  7. Save your changes and close the text editor.
  8. Start WorkFusion Studio and open the recording.
  9. Repeat the procedure for all the recordings created with an older version, which fail to migrate automatically.
Model does not contain namespace URI

Symptoms

SYMPTOMS

When you launch a recording, you get this error, as Recorder does not support migration from later to earlier versions.

Resolution

RESOLUTION

Open your recording with any text editor and manually change the version of Intelligent Automation Cloud – Express or Business – to the one installed on your machine. Follow the same steps described above for Unable to open recording.

Error executing WebElementAction

Symptoms

SYMPTOMS

Error executing TemplateAction

...

Caused by: org.openqa.selenium.WebDriverException: unknown error: call function result missing 'value'

Resolution

RESOLUTION

If your RPA scripts stopped working after browser update, you need to do the following steps.

Chrome Driver

  1. Download the latest driver from https://sites.google.com/a/chromium.org/chromedriver/downloads.
  2. Replace the old driver in IntelligentAutomationCloud\RPA\rpa-grid\drivers\windows\x32.

Firefox Driver

  1. Download the latest drivers (both x32 and x64) from https://github.com/mozilla/geckodriver/releases.
  2. Replace old drivers in the following directories:
    1. geckodriver-vx-win32.zip > in IntelligentAutomationCloud\RPA\rpa-grid\drivers\windows\x32
    2. geckodriver-vx-win64.zip > in IntelligentAutomationCloud\RPA\rpa-grid\drivers\windows\x64
Bot cannot click on needed element in Internet Explorer

Symptoms

SYMPTOMS

You use Internet Explorer as your browser for automating, but a Bot cannot click on the needed element, no matter what mouse click option you select.

Resolution

RESOLUTION

Make sure your Windows display scaling is set up to 100%. To perform the needed changes, do as follows.

  1. Go to Start > Settings > System > Display.
  2. In Scale and Layout, select 100% for Change the size of text, apps, and other items. The changes apply automatically.
Recording is not playing: Unable to connect with Robot

Valid up to version 2.3.0 

Symptoms

SYMPTOMS

You click Play recording, but the Unable to connect with Robot message emerges.

Resolution 1

RESOLUTION 1

Check Bot Manager status. Perhaps, it is not started.

  1. To start Bot manager, open the tray menu and click Start in the Bot Manager section.

    Mind that the tray menu is deprecated since RPA Express 2.3.0.

  2. If it does not help, choose All Components > Restart.

Resolution 2

RESOLUTION 2

If the status of Bot Manager is Started, do as follows.

  1. Click Details>> on the window with the error message. If the error text contains "Caused by: org.openqa.selenium.WebDriverException: Unable to parse remote response: <!DOCTYPE html>", open Server Profiles. For that, go to Window > Preferences > WorkFusion Studio > Server Profiles.
  2. Check the value of Bot Relay URL. The URL should be: http://localhost:15444/wd/hub
  3. If it is wrong or missing, edit/insert it manually.
  4. Click Apply, then OK.
  5. If the URL is correct, but exception occurs, please check whether you use proxy. You may find some settings in your Internet Explorer browser like below.
  6. If you don't use proxy and still get this exception, please refer to your local IT team in order to provide access to the URL.
Recording is not playing: java.net.MalformedURLException: no protocol

Symptoms

SYMPTOMS

You click Play recording, but it fails with the following exception.

Resolution

RESOLUTION

  1. Open Window > Preferences > Workfusion Studio > Server Profiles, or click Server Profile: Default > Manage Profiles on the Components tab in WorkFusion Studio.
  2. Check whether default profile settings are populated according to the following guide: Preferences.
  3. If not, populate all the necessary fields, then press Apply and Close.
Recording is not playing: Cannot find active server profile

Symptoms

SYMPTOMS

You click Play recording, but it fails with the following exception.

Resolution

RESOLUTION

  1. Open Window > Preferences > Workfusion Studio > Server Profiles, or click Server Profile: Default > Manage Profiles on the Components tab in WorkFusion Studio.
  2. If you see the error "Cannot find active server profile" in Server Profile (see below), you need to delete folder C:\Users\%USER_NAME%\.eclipse and check whether the server profile has been found and is not empty.
  3. If the server profile is empty, populate the fields as described in this guide: Preferences.

    Note

    Do the next steps only in case of the folder C:\Users\%USER_NAME%\.eclipse is absent. In case you have it and can remove, see steps 1-3 above.

  4. If the folder C:\Users\%USER_NAME%\.eclipse is absent, and/or the server profile is not saved even after manual entering the data, do as follows.
    1. Open Window > Preferences > General > Security > Secure Storage.
    2. Uncheck Windows Integrated (64 bit), press Apply, and then OK.

      Do not click on the Change Password button.

    3. Enter your own password and hints for recovering password as shown below.

    4. Restart Intelligent Automation Cloud – Express or Business – and launch WorkFusion Studio.
    5. In the password window that appears, enter the password you have previously set, go to WorkFusion Studio, and check whether default server profile is filled in.
Recording is not playing: Unable to read file

Symptoms

SYMPTOMS

You click Play recording, but the message "Unable to read file" appears.

Resolution

RESOLUTION

Check that the details in all actions are filled in completely and there are no empty drop-downs, paths to files/folders or conditions. You can see which element is missing in the error log by clicking the Details>> button.

Recording is not playing: Unexpected error during execution. Secret entry not found

Valid since version 2.1.0

Symptoms

SYMPTOMS

After a bot starts playing, it fails with the following exception:

Resolution

RESOLUTION

This exception means that there is no secret entry for Secrets Vault variables in your script. Before playing your script, make sure you have the required secret entry in the guide. Pay attention that the secret entry name should be the same as in the exception. In this case, you should have the salesforce_cred secret entry as shown below.

Recording is not playing: Unexpected error during execution

Valid since version 2.1.0

Symptoms

SYMPTOMS

After a bot starts playing, it fails with the following exception.

Resolution

RESOLUTION

This exception means that a secret variable doesn't have any default secret entry. Before playing your script, make sure you have the required secret entry as described in the guide. Alternatively, you can remove this variable from the script.

RPA Recorder gets too slow

Symptoms

SYMPTOMS

WorkFusion Studio is working extremely slow.

Resolution

RESOLUTION

The maximum memory allocation pool for Java Virtual Machine (JVM) has been exceeded by WorkFusion Studio.

  1. Make sure that WorkFusion Studio is closed.
  2. Go to Studio folder (by default C:\IntelligentAutomationCloud\Studio\).
  3. Find and open the WorkFusion Studio configuration file (workfusion-studio.ini).
  4. Find the Xmx property. Default value is 1024m that equals to 1024 MB of memory.
  5. Change the value of the flag to 2048m to double the size of the memory pool.
  6. Save and close the configuration file.
  7. Start WorkFusion Studio.
"Ctrl+Enter" keystroke combination not working

Valid up to version 2.3.0

Symptoms

SYMPTOMS

Keystroke combination "Ctrl + Enter" is neither accepted nor shown in the Key combination box.

Resolution

RESOLUTION

By default, the "Ctrl + Enter" keystroke is accepted with all the windows minimized. Do as follows.

  1. Add Keystrokes to your Actions Flow.
  2. Click Change and minimize all windows.
  3. Hit Ctrl + Enter for the combination to appear in the details.

There is also a workaround to make it work without minimizing all the open windows. You can record "Ctrl + Enter" using RPA Recorder.

  1. Click Insert recording.
  2. After recording starts, click "Ctrl + Enter" and stop the recording. You will get the Enter Keystrokes "Ctrl + Enter" action.

After that, you can use this recording anywhere you need to insert the "Ctrl + Enter" keystroke.

Error executing OCR action: URL is not absolute

Symptoms

SYMPTOMS

OCR action fails and returns an error "Error executing OCR action: URL is not absolute".

Resolution

RESOLUTION

  1. First you need to check if the server profile is filled in. If not, you can fill it in manually using this guide.
    image
  2. If this does not help, check your Intelligent automation Cloud – Express and Business – version as it might require an update. Go to Control Panel > Programs > Programs and Features as seen here.
  3. If you have the latest version (no update available) you'll need to proceed with the investigation. Go to the community forum and describe your issue.
Error executing OCR action: OcrException cannot be found

Symptoms

SYMPTOMS

An execution error occurs.

Resolution

RESOLUTION

  1. First, check if the OCR status and the remaining number of pages to be processed under the current OCR license on the Server Components tab.
  2. If you see 0 pages left, you'll need to purchase an OCR license.

  3. If you still have pages remaining, check your Intelligent Automation Cloud – Express or Business – version, as it might require an update. Go to Control Panel > Programs > Programs and Features as seen on the picture below.
  4. If you have the latest version (no update available), you'll need to proceed with the investigation. Go to the community forum and describe your issue.

Window cannot be recognized in SAP GUI

Valid since version 2.3.0

Symptoms

SYMPTOMS

While automating SAP GUI and using the Window action, it cannot be recognized. For example, you entered the selector of the Save As window using Inspector.

While script execution, an exception occurs.

Resolution

RESOLUTION

  1. Check your SAP GUI UI theme.
  2. Change your UI theme to Blue Crystal or Classical if you use any other theme.
  3. In case you use one of these themes or this solution doesn't help, collect and zip WorkFusion Studio log files as described here and escalate on the community forum with a short description of your issue.
While opening execution-result.log.csv in WorkFusion Studio exception appears

Symptoms

SYMPTOMS

While trying to open execution-result.log.csv in WorkFusion Studio in Excel after script execution, the following exception appears.

That happens due to the total length of the file name and path.

Resolution

RESOLUTION

Make sure that whole file path to the execution-result.log.csv file is not less:

  • 200 characters for OneDrive (including spaces and slashes)
  • 260 characters in case of local drive (including spaces and slashes)

In case it exceeds these values, move your project or whole the Workspace to a short path, and remove unnecessary folders hierarchy.

Oracle JInitiator version is too low. Please install version 1.1.8.2 or higher

Symptoms

SYMPTOMS

While trying to log in to some servlet (Oracle Form), a similar exception occurs.

Resolution

RESOLUTION

Usually, the exception means that the Java version is old, e.g., 7. But our application has its own Java package with version 1.8, so this is not an issue with it. To fix this exception, do as follows.

  1. Open Java Control Panel and select the Java tab.
  2. Open View and enter -Djava.vendor="Sun Microsystems Inc. in the Runtime Parameters field.

  3. Click OK and close Java Control Panel.
  4. Run your script.