Installation

The section describes how you can solve issues that may occur during Intelligent Automation Cloud – Express and Business – installation.

UI Expand
titleError code 0x80070661
Info

Valid up to version 

Status
colourGreen
title2.1.0

Warning
titleSymptoms

Status
colourRed
titleSymptoms

Installation failed with error code 0x80070661.

Tip
titleResolution

Status
colourGreen
titleResolution

  1. Your target machine has 32-bit operating system installed.
  2. Check that you have 64-bit operating system (32-bit is not supported).

UI Expand
titleError code 0x80070643
Warning
titleSymptoms

Status
colourRed
titleSymptoms

Installation failed with error code 0x80070643. This exception can have different causes, please see several solutions below.

Tip
titleResolution

Status
colourGreen
titleResolution 1

  1. Some of .msi files can be moved to quarantine by anti-virus or anti-malware software.
  2. Disable your antivirus or anti-malware software temporarily, restore file, and run IntelligentAutomationCloudInstaller.exe once again.
  3. If this doesn't help, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.
Tip
titleResolution

Status
colourGreen
titleResolution 2

  1. Some of ports on your PC are blocked by your organization policy or firewall. You can find more information here — Express/Business Installation - Preconditions.
  2. Check with your local IT department and after fixing the issue, run IntelligentAutomationCloudInstaller.exe once again.
  3. If this doesn't help, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.
Tip
titleResolution

Status
colourGreen
titleResolution 3

  1. If you have policy that prevents install software on C: drive, please try to use another folder or another drive instead of default while installing. For example,
    C:\Test
    D:\RPAExpress
    C:\Program Files\RPAExpress (or alternatively C:\Program Files (x86)\RPAExpress depending on your system)
  2. Run IntelligentAutomationCloudInstaller.exe again and check the results.
  3. If this doesn't help, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.
UI Expand
titleError code 0x80070570
Warning
titleSymptoms

Status
colourRed
titleSymptoms

Installation failed with error code 0x80070570.

Tip
titleResolution

Status
colourGreen
titleResolution

  1. Make sure you have completely extracted the content of the installation archive (IntelligentAutomationCloudInstaller.zip) on your local drive.
  2. Disable your antivirus or anti-malware software.
  3. If this doesn't help, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.
UI Expand
titleError code 0x80070005
Warning
titleSymptoms

Status
colourRed
titleSymptoms

Installation failed with error code 0x80070005.

Tip
titleResolution

Status
colourGreen
titleResolution

In most cases it means that you don't have access to the folder C:\ProgramData\Package Cache. To check it, do the following steps.

  1. Create a folder in C:\ProgramData\Package Cache like C:\ProgramData\Package Cache\test, then try to copy any file from your PC and paste to this folder.
  2. If you get the message below, ask to obtain an appropriate permission from your local IT department in order to resolve the issue.

  3. If you are able to create folder in C:\ProgramData\Package Cache, but the issue still exists, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.
UI Expand
titleUpdate admin user in PostgreSQL database was failed
Warning
titleSymtomps

Status
colourRed
titleSymptoms

The following window is being displayed during installation.

Tip
titleResolution

Status
colourGreen
titleResolution

  1. Check whether your system meets the system requirements.
  2. If it does, check with your local IT team whether port 15423 is blocked. In case it is blocked, ask to unblock it, and run the installation once again.
  3. If the port is not blocked and installation still fails with the same error, collect and zip installation log files as described here and escalate on the forum with a short description of your issue.

Launch

The section describes how you can solve issues that may occur during launch of Express Edition or Business Edition.

UI Expand
titleThe application shortcut doesn't start: a pop-up window is showing
Info

Valid up to version  

Status
colourGreen
title2.1.5

Warning
titleSymptoms

Status
colourRed
titleSymptoms

After clicking on the application shortcut, the following window is shown.

Tip
titleResolution 1

Status
colourGreen
titleResolution 1

  1. Right-click on the shortcut on your desktop.
  2. Press Change and find the application file wscript.exe in C:\Windows\System32 on your PC (see the screen below).
  3. Select this file, click Apply, and close shortcut properties.
  4. Run RPA Express.
Tip
titleResolution 2 (if Microsoft Windows Based Script Host is removed from PC)

Status
colourGreen
titleResolution 2

  1. Open folder C:\RPAExpress\RPA\wfagent.
  2. Create a file with the name express.bat and add content as below.

    Code Block
    START /B ..\..\Applications\Java\bin\javaw -Dagent.showIntro=true -Dloader.path=lib -Dhttp.nonProxyHosts="localhost|127.0.0.1" -Djava.awt.headless=false  -Dagent.desktopType=RPA_EXPRESS -Dfile.encoding=UTF-8 -Xmx500m -jar status-agent.jar --spring.config.location=./express.yml


  3. Open the shortcut properties and change attributes as shown below.

  4. Launch RPA Express.
UI Expand
titleThe application shortcut doesn't start: Windows Script Host access is disabled
Info

Valid up to version  

Status
colourGreen
title2.1.5

Warning
titleSymptoms

Status
colourRed
titleSymptoms

After clicking on the application shortcut, the following window is shown.

Tip
titleResolution

Status
colourGreen
titleResolution

Info

If you don't have permissions to change registry, contact your IT department.

  1. Type regedit in the Run box and press Enter to open the Registry Editor.
  2. Navigate to the following key: HKEY_CURRENT_USER\Software\Microsoft\Windows Script Host\Settings
  3. On the right panel, Value name is Enabled. If you see the entry 0, the Windows Script Host access is disabled on your Windows machine. To enable, double-click it and set Value data to 1.

    1. A value of 1 enables Windows Script Host
    2. A value of 0 disables Windows Script Host
  4. Click OK and exit the Registry. 
Info

If you don’t see this entry, go to HKEY_LOCAL_MACHINE\Software\Microsoft\Windows Script Host\Settings and repeat the steps above.

UI Expand
titlePlatform Monitor page is unreachable
Info

Valid up to version 

Status
colourGreen
title2.3.0

Warning
titleSymptoms

Status
colourRed
titleSymptoms

Connection to Platform Monitor via localhost cannot be established.

Tip
titleResolution

Status
colourGreen
titleResolution

Your computer is connected to the network via a proxy server, and the connection is managed by network administrators.

  1. Go to Control Panel > Internet Options and click LAN settings.
  2. Check if there is a proxy specified in Automatic configuration (it cannot be changed).
  3. Contact your network administrator and request to add the following resources to exceptions:
    • localhost
    • 127.0.0.1
UI Expand
titleControl Tower cannot be started
Info

Valid up to version 

Status
colourGreen
title2.3.0

Warning
titleSymptoms

Status
colourRed
titleSymptoms

You tried to start Control Tower from the tray menu, but the status is Not started after several tries.

Warning

Mind that the tray menu is deprecated since RPA Express

Status
colourGreen
title2.3.0
. Starting from
Status
colourGreen
title2.3.0
, Control Tower is enabled on the Components tab in WorkFusion Studio.

Tip
titleResolution

Status
colourGreen
titleResolution

  1. Check whether your PC meets the system requirements. Note that Control Tower takes a lot of RAM, so you may need to close other active applications while Control Tower is starting.

    Warning

    It can take up to 10-15 minutes, depending on the machine's properties, to start Control Tower.

  2. If your machine meets the system requirements, but Control Tower still hasn't started, try starting it using Platform Monitor.

    1. Open Platform Monitor from the tray menu. Mind that the tray menu is deprecated since RPA Express
      Status
      colourGreen
      title2.3.0
       as well.
    2. Go to System Processes and check components: 
      1. mysqld
      2. postgress
      3. tomcat
    3. They should have status stopped as on the screenshot below.
    4. Press Actions > Start for each of these components.
    5. In the window below, click OK and wait till the status of the components changes to running.

After that, you can log into Control Tower by opening this link in your browser: http://localhost:15280/workfusion/login

Warning

If the above steps are of no help, escalate on the community forum with a detailed description of your issue.

UI Expand
titleBot Manager cannot be started
Excerpt
Info

Valid up to version 

Status
colourGreen
title2.3.0

Warning
titleSymptoms

Status
colourRed
titleSymptoms

Bot Manager is stopped and cannot be started from the tray menu, while your machine is not connected to the network either by Ethernet or Wi-Fi.

Tip
titleResolution

Status
colourGreen
titleResolution

  1. Enable a Network interface.

    Note
    titleImportant note

    It does not mean you should have access to Internet.

  2. Exit RPA Express.
  3. Install Microsoft Loopback Adapter as described on Microsoft TechNet website or follow the instruction below (for Windows 10).
    1. Open My Computer > Properties.
    2. Open Device Manager.
    3. Go to Action and select Add legacy hardware.
    4. Click Next in Add Hardware Wizard.
    5. Choose Install the hardware that I manually select from a list (Advanced) and click Next.
    6. Select Network adapters in the hardware types and click Next.
    7. In the Select the device driver dialog, choose:
      1. Manufacturer – Microsoft
      2. Model – Microsoft KM-TEST Loopback Adapter

      and click Next.
    8. Click Next to install.
    9. Wait until the installation ends and click Finish to complete.
    10. Open Device Manager to make sure Lookback Adapter is installed and enabled.
  4. Wait until the connection is established.
  5. Open Command Prompt and use ipconfig to check the status of all network interfaces. Make sure Loopback Adapter has got the ip-addresses.
  6. Start RPA Express.
  7. Check Bot Manager status in the tray menu.

    Warning

    Mind that the tray menu is deprecated since RPA Express

    Status
    colourGreen
    title2.3.0
    .

Components

The section describes how you can solve issues, that may occur while working with Express Edition or Business Edition.

UI Expand
titleThe application does not respond
Warning
titleSymptoms

Status
colourRed
titleSymptoms

Intelligent Automation Cloud – Express or Business – has got non-responsive and stays so for a long time.

Tip
titleResolution

Status
colourGreen
titleResolution

You should end all the processes manually.

For that purpose, we recommend to use Process Explorer (Windows Sysinternals tool), as the standard Windows Task Manager is not convenient to handle multiple processes.

  1. Go to Process Explorer page. There, you can find a description of the tool and the download link.
  2. Download Process Explorer and unpack it to a local folder on your computer.
  3. Start Process Explorer (procexp.exe or procexp64.exe) and accept EULA. Process Explorer opens.
  4. Find the following tasks:
    1. IntelligentAutomationCloud.Agent.exe with multiple sub-tasks (workfusion-studio.exe, java.exe, mysqld.exe, minio.exe, cmd.exe);

    2. cmd.exe with sub-tasks postgres.exe

  5. Select the task, right-click, and choose Kill Process Tree in the context menu.

  6. Do the same for the second task.

UI Expand
titleComponents links are not opening in default browser
Warning
titleSymptomps

Status
colourRed
titleSymptoms

Intelligent Automation Cloud Business looks launched successfully and doesn't show any warnings, but when clicking on links on the Components tab, nothing happens.

Tip
titleResolution

Status
colourGreen
titleResolution

  1. Check whether the following links are not working as well.
  2. If the links above are not working, change your default browser (for example, from Chrome to Firefox, or Internet Explorer) and check the links once again. 
  3. If the links work in another browser, check which extensions or plugins you have in your usual default browser. Try to switch them one by one and check how the links work. 
  4. When you found an extension that prevents to open the links, switch it off or configure to allow Intelligent Automation Cloud Business links to launch in the browser.
    Known case: Norton Safe Web extension for Chrome prevents to launch Business Edition links.
UI Expand
titleServer components are not found
Info

Valid since version 

Status
colourGreen
title2.3.0
 

Warning
titleSymptoms

Status
colourRed
titleSymptoms

After launching the application, you may see the message like below.

Tip
titleResolution 1

Status
colourGreen
titleResolution 1

  1. At first, check which installation type you have. If you installed Express Edition, it doesn't contain server components like Control Tower and File Storage. In this case, you won't be able to see these components on the Components tab.
  2. If you have Business Edition, make sure you have selected Development Workstation and Server option during installation.
  3. If you downloaded the right version and selected Development Workstation and Server, but the issue still persists, check your default server profile settings in Window > Preferences > WorkFusion Studio > Server Profiles. For non-server local installation, they should be like on the screenshot below. For more details about this window, see here.
  4. If the Preferences settings are correct, there are several scenarios to follow.
    1. Open Control Tower URL from the profile in browser. In case it shows the Control Tower login page, it means that your components work. Reopen WorkFusion Studio, it should show Components as usual.
    2. Close all unnecessary applications and exit Intelligent Automation Cloud Business. Make sure that it closes completely. Reboot your PC and launch Business Edition only, wait till it loads, and after that wait for 5-10 minutes for the components links to appear. 
  5. If it doesn't work, collect files from the folder C:\IntelligentAutomationCloud\Agent\Logs\ and WorkFusion Studio logs and escalate on the community forum.
Tip
titleResolution 2

Status
colourGreen
titleResolution 2

If Resolution 1 didn't help, close Intelligent Automation Cloud (Express or Business).

  1. Go to the folder C:\Users\<user_name>\.

  2. Find the folder named workfusion-workspace.

  3. Create the new folder with the name workfusion-workspace2 and copy all the files from the previous one.

  4. Start Intelligent Automation Cloud (Express or Business), wait for several minutes, and check the Components tab.

  5. If this doesn't help as well, collect and zip WorkFusion Studio log files as described here and escalate on the community forum with a short description of your issue.

Control Tower

UI Expand
titleNo samples of business processes in Control Tower
Warning
titleSymptoms

Status
colourRed
titleSymptoms

You see empty Business Processes list in Control Tower, though there should be samples with business processes.

Tip
titleResolution

Status
colourGreen
titleResolution

  1. Run your Control Tower if it is not started and open it.
  2. Go to the Business Processes list and click on the button next to Create New, and press Import package.
  3. Press Add in order to upload files.
  4. Find in the dialog window C:\Users\<user_name>\ControlTower\Samples. You should see several zip-archives and csv-files.
  5. Choose one of archives and press Open. You should see the following screen.
  6. Press Preview Package, wait a bit while the Import package button becomes available and press it.
  7. After that, you can see sample business process in the list. 

UI Expand
titleScheduled process doesn't appear in Business Processes list in Control Tower
Warning
titleSymptoms

Status
colourRed
titleSymptoms
 

When you set up schedule for some process it doesn't appear on the Business Processes tab.

Tip
titleResolution

Status
colourGreen
titleResolution

  1. Check that you have chosen the whole business process while scheduling, not a task.
  2. Correct the schedule for the whole business process and you will see it in the list of all business processes.
UI Expand
titleThe remote device or resource won't accept the connection
Warning
titleSymptoms

Status
colourRed
titleSymptoms

You cannot access Control Tower and WorkSpace. The message "The remote device or resource won't accept the connection" appears.

Tip
titleResolution

Status
colourGreen
titleResolution

This happens because of the use of proxy. Close your RPA Express completely and follow these steps:

  1. Press Win+R.
  2. Type in inetcpl.cpl.
  3. As soon as Internet properties open, switch to the Connections tab and select LAN settings.
  4. In the Local Area Network Settings window, uncheck the Use a proxy server for your LAN option. Automatically detect settings must be still checked though.
  5. Apply the changes.
UI Expand
titleRecording is playing in RPA Recorder but not in Control Tower
Warning
titleSymptoms

Status
colourRed
titleSymptoms

You play the recording in WorkFusion Studio and it runs without errors. But after publishing the recording to Control Tower, it is not playing.

Tip
titleResolution

Status
colourGreen
titleResolution

If you use paths to files in your actions (Enter Keystrokes, Launch Application), make sure all backslashes are doubled, for example: C:\\Program Files\\Your Super Software\\Installer.msi

WorkFusion Studio

UI Expand
titleUnable to open recording

Anchor
cannotreadfile
cannotreadfile

Warning
titleSymptoms

Status
colourRed
titleSymptoms

While opening a recording created with a older version of Intelligent Automation Cloud – Express or Business, migration fails with the following error.

When you click OK, RPA Recorder cannot open the recording.

Tip
titleResolution

Status
colourGreen
titleResolution

Your recording is created with an older version of Intelligent Automation Cloud – Express or Business – and cannot migrate automatically due to changes in the action model.

Anchor
Edit version
Edit version

  1. Close the tab that shows the error and close WorkFusion Studio.
  2. Go to your workspace folder (by default C:\Users\%username%\workfusion-workspace\rpae_project).
  3. Find the .rpae file you want to run.
  4. Open it with any text editor, e.g., Notepad.
  5. Find the string in the XML header which contains a wrong version number (see example below).

    Code Block
    languagexml
    xmlns:recorder="http://www.workfusion.com/recorder/v1.0.0"
  6. Change the namespace manually to the version of Express or Business Edition currently installed on your machine (for example, 2.4.0)

    Code Block
    languagexml
    xmlns:recorder="http://www.workfusion.com/recorder/v2.4.0"
  7. Save your changes and close the text editor.
  8. Start WorkFusion Studio and open the recording.
  9. Repeat the procedure for all the recordings created with an older version, which fail to migrate automatically.
UI Expand
titleModel does not contain namespace URI
Warning
titleSymptoms

Status
colourRed
titleSymptoms

When you launch a recording, you get this error, as Recorder does not support migration from later to earlier versions.

Tip
titleResolution

Status
colourGreen
titleResolution

Open your recording with any text editor and manually change the version of Intelligent Automation Cloud – Express or Business – to the one installed on your machine. Follow the same steps described above for Unable to open recording.

UI Expand
titleError executing WebElementAction
Warning
titleSymptoms

Status
colourRed
titleSymptoms

Error executing TemplateAction

...

Caused by: org.openqa.selenium.WebDriverException: unknown error: call function result missing 'value'

Tip
titleResolution

Status
colourGreen
titleResolution

If your RPA scripts stopped working after browser update, you need to do the following steps.

Chrome Driver

  1. Download the latest driver from https://sites.google.com/a/chromium.org/chromedriver/downloads
  2. Replace the old driver in IntelligentAutomationCloud\RPA\rpa-grid\drivers\windows\x32

Firefox Driver

  1. Download the latest drivers(both x32 and x64) from https://github.com/mozilla/geckodriver/releases
  2. Replace old drivers in the following directories:
    1. geckodriver-vx-win32.zip > in IntelligentAutomationCloud\RPA\rpa-grid\drivers\windows\x32
    2. geckodriver-vx-win64.zip > in IntelligentAutomationCloud\RPA\rpa-grid\drivers\windows\x64
UI Expand
titleBot cannot click on the needed element in Internet Explorer
Warning
titleSymptoms

Status
colourRed
titleSymptoms

You use Internet Explorer as your browser for automating, but a Bot cannot click on the needed element, no matter what mouse click option you select.

Tip
titleResolution

Status
colourGreen
titleResolution

Make sure your Windows display scaling is set up to 100%. To perform the needed changes, do as follows.

  1. Go to Start > Settings > System > Display.
  2. In Scale and Layout, select 100% for Change the size of text, apps, and other items. The changes apply automatically.
UI Expand
titleRecording is not playing: Unable to connect with Robot
Info

Valid up to version 

Status
colourGreen
title2.3.0
 

Warning
titleSymptoms

Status
colourRed
titleSymptoms

You click Play recording, but the Unable to connect with Robot message emerges.

Tip
titleResolution 1

Status
colourGreen
titleResolution 1

Check Bot Manager status. Perhaps, it is not started.

  1. To start Bot manager, open RPA Express tray menu and click Start in the Bot Manager section.

    Warning

    Mind that the tray menu is deprecated since RPA Express

    Status
    colourGreen
    title2.3.0
    .

  2. If it does not help, choose All Components > Restart
Tip
titleResolution 2

Status
colourGreen
titleResolution 2

If the status of Bot Manager is Started, do as follows.

  1. Click Details>> on the window with the error message.
  2. If the error text contains: Caused by: org.openqa.selenium.WebDriverException: Unable to parse remote response: <!DOCTYPE html>, open Server Profiles. For that, go to Window > Preferences > WorkFusion Studio > Server Profiles.
  3. Check the value of Bot Relay URL. The URL should be: http://localhost:15444/wd/hub
  4. If it is wrong or missing, edit/insert it manually.
  5. Click Apply, then OK.
  6. If the URL is correct, but exception occurs, please check whether you use proxy. You may find some settings in your Internet Explorer browser like below
  7. If you don't use proxy and still get this exception, please refer to your local IT team in order to provide access to the URL.
UI Expand
titleRecording is not playing: java.net.MalformedURLException: no protocol
Warning
titleSymptoms

Status
colourRed
titleSymptoms

You click Play recording, but it fails with the following exception.

Tip
titleResolution

Status
colourGreen
titleResolution

  1. Open Window > Preferences > Workfusion Studio > Server Profiles, or click Server Profile: Default > Manage Profiles on the Components tab in WorkFusion Studio.
  2. Check whether default profile settings are populated according to the following guide: Preferences.
  3. If not, populate all the necessary fields, then press Apply and Close.
UI Expand
titleRecording is not playing: Cannot find active server profile
Warning
titleSymptoms

Status
colourRed
titleSymptoms

You click Play recording, but it fails with the following exception.

Tip
titleResolution

Status
colourGreen
titleResolution

  1. Open Window > Preferences > Workfusion Studio > Server Profiles, or click Server Profile: Default > Manage Profiles on the Components tab in WorkFusion Studio.
  2. If you see the error "Cannot find active server profile" in Server Profile (see below), you need to delete folder C:\Users\%USER_NAME%\.eclipse and check whether the server profile has been found and is not empty.
  3. If the server profile is empty, populate the fields as described in this guide: Preferences.

    Warning
    titleNote

    Do the next steps only in case of the folder C:\Users\%USER_NAME%\.eclipse is absent. In case you have it and can remove, see steps 1-3 above.

  4. If the folder C:\Users\%USER_NAME%\.eclipse is absent, and/or the server profile is not saved even after manual entering the data, do as follows.
    1. Open Window > Preferences > General > Security > Secure Storage.
    2. Uncheck Windows Integrated (64 bit), press Apply, and then OK.

      Warning

      Do not click on the Change Password button.

    3. Enter your own password and hints for recovering password as shown below.

    4. Restart Intelligent Automation Cloud – Express or Business – and launch WorkFusion Studio.
    5. In the password window that appears, enter the password you have previously set, go to WorkFusion Studio, and check whether default server profile is filled in.
UI Expand
titleRecording is not playing: Unable to read file
Warning
titleSymptoms

Status
colourRed
titleSymptoms

You click Play recording, but the message "Unable to read file" appears.

Tip
titleResolution

Status
colourGreen
titleResolution

Check that the details in all actions are filled in completely and there are no empty drop-downs, paths to files/folders or conditions. You can see which element is missing in the error log by clicking the Details>> button.

UI Expand
titleRecording is not playing: Unexpected error during execution. Secret entry not found
Info

Valid since version 

Status
colourGreen
title2.1.0

Warning
titleSymptoms

Status
colourRed
titleSymptoms

After a bot starts playing, it fails with the following exception:

Tip
titleResolution

Status
colourGreen
titleResolution

This exception means that there is no secret entry for Secrets Vault variables in your script. Before playing your script, make sure you have the required secret entry in the guide. Pay attention that the secret entry name should be the same as in the exception. In this case, you should have the salesforce_cred secret entry as shown below.

UI Expand
titleRecording is not playing: Unexpected error during execution
Info

Valid since version 

Status
colourGreen
title2.1.0

Warning
titleSymptoms

Status
colourRed
titleSymptoms

After a bot starts playing, it fails with the following exception.

Tip
titleResolution

Status
colourGreen
titleResolution

This exception means that a secret variable doesn't have any default secret entry. Before playing your script, make sure you have the required secret entry as described in the guide. Alternatively, you can remove this variable from the script.

UI Expand
titleRecorder gets too slow
Warning
titleSymptoms

Status
colourRed
titleSymptoms

WorkFusion Studio is working extremely slow.

Tip
titleResolution

Status
colourGreen
titleResolution

The maximum memory allocation pool for Java Virtual Machine (JVM) has been exceeded by WorkFusion Studio.

  1. Make sure that WorkFusion Studio is closed.
  2. Go to Studio folder (by default C:\IntelligentAutomationCloud\Studio\).
  3. Find and open the WorkFusion Studio configuration file (workfusion-studio.ini).
  4. Find the Xmx property. Default value is 1024m that equals to 1024 MB of memory.
  5. Change the value of the flag to 2048m to double the size of the memory pool.
  6. Save and close the configuration file.
  7. Start WorkFusion Studio.
UI Expand
title"Ctrl+Enter" keystroke combination not working
Info

Valid up to version 

Status
colourGreen
title2.3.0

Warning
titleSymptoms

Status
colourRed
titleSymptoms

Keystroke combination "Ctrl + Enter" is neither accepted nor shown in the Key combination box.

Tip
titleResolution

Status
colourGreen
titleResolution

By default, the "Ctrl + Enter" keystroke is accepted with all the windows minimized. Do as follows.

  1. Add Keystrokes to your Actions Flow.
  2. Click Change and minimize all windows.
  3. Hit Ctrl + Enter for the combination to appear in the details.

There is also a workaround to make it work without minimizing all the open windows. You can record "Ctrl + Enter" using RPA Recorder.

  1. Click Insert recording.
  2. After recording starts, click "Ctrl + Enter" and stop the recording. You will get the Enter Keystrokes "Ctrl + Enter" action.

After that, you can use this recording anywhere you need to insert the "Ctrl + Enter" keystroke.

UI Expand
titleError executing OCR action: URL is not absolute
Warning
titleSymptoms

Status
colourRed
titleSymptoms

OCR action fails and returns an error "Error executing OCR action: URL is not absolute".

Tip
titleResolution

Status
colourGreen
titleResolution

  1. First you need to check if the server profile is filled in. If not, you can fill it in manually using this guide.
    image
  2. If this does not help, check your Intelligent automation Cloud – Express and Business – version as it might require an update. Go to Control Panel > Programs > Programs and Features as seen here.

    Here you can find a list of all the versions, including the latest one, for a reference.
  3. If you have the latest version (no update available) you'll need to proceed with the investigation. Go to the community forum and describe your issue.
UI Expand
titleError executing OCR action: OcrException cannot be found
Warning
titleSymptoms

Status
colourRed
titleSymptoms

Execution error occurs:

Tip
titleResolution

Status
colourGreen
titleResolution

  1. First, check if the OCR status and the remaining number of pages to be processed under the current OCR license on the Components tab.
  2. If you see 0 pages left, you'll need to purchase an OCR license.

  3. If you still have pages remaining, check your Intelligent Automation Cloud – Express or Business – version, as it might require an update. Go to Control Panel > Programs > Programs and Features as seen on the picture below.

    Here you can find a list of all the versions, including the latest one, for a reference.
  4. If you have the latest version (no update available), you'll need to proceed with the investigation. Go to the community forum and describe your issue.

UI Expand
titleWindow cannot be recognized in SAP GUI
Info

Valid since version 

Status
colourGreen
title2.3.0

Warning
titleSymptoms

Status
colourRed
titleSymptoms

While automating SAP GUI and using the Window action, it cannot be recognized. For example, you entered the selector of the Save As window using Inspector.

While script execution, an exception occurs.

Tip
titleResolution

Status
colourGreen
titleResolution

  1. Check your SAP GUI UI theme.
  2. Change your UI theme to Blue Crystal or Classical if you use any other theme.
  3. In case you use one of these themes or this solution doesn't help, collect and zip WorkFusion Studio log files as described here and escalate on the community forum with a short description of your issue.


How to Send Logs


Tip
titleHint

Intelligent Automation Cloud – Express or Business – logs contain information about events and messages produced by Intelligent Automation Cloud components, and a short list of the system properties, such as OS version, CPU type, and RAM size.

No sensitive information is collected and included.

It's safe to send them out via the community forum as a private message or an attachment to your post.

UI Expand
titleInstallation logs

If installation failed and you see any exception after it, and your PC meets our system requirements, perform the following steps.

  1. Go to the C:\Users\%user_name%\AppData\Local\Temp folder.
  2. Find all the files that start with "WorkFusion_Intelligent_Automation_Cloud_" and have .log extension.
    For example: 
    WorkFusion_Intelligent_Automation_Cloud_20190905113212.log
    WorkFusion_Intelligent_Automation_Cloud_20190907113252_001_WorkFusionControlTower.log
    WorkFusion_Intelligent_Automation_Cloud_20190907113252_<any_symbols>.log

  3. Create a ZIP archive with these files.
  4. Post this archive and description of your issues to WorkFusion Forum.
UI Expand
titleComponents logs (valid up to version 2.3.0)
Info

Valid up to version 

Status
colourGreen
title2.3.0

If one of the server components is not working properly after a successful installation, and your PC meets System Requirements, complete the following steps.

Warning

Mind that the tray menu and Platform Monitor are deprecated since RPA Express

Status
colourGreen
title2.3.0
.

  1. Open Platform Monitor > Command Board (from the tray menu or type http://localhost:15100/commands in the browser address line).
  2. Click the Execute button opposite to the required command (command which starts a failed/unavailable component).
  3. Copy response text and send it to the community forum.
UI Expand
titleWorkFusion Studio logs
  1. Go to %install_dir%\Studio\logs (the default path is C:\IntelligentAutomationCloud\Studio\logs).
  2. Create a ZIP archive of the folder contents.
  3. Post this archive and description of your issues to the community forum.
UI Expand
titleRPA hub and node logs
  1. Go to %install_dir%\RPA\logs\ (the default path is C:\IntelligentAutomationCloud\RPA\logs\).
  2. Create a ZIP archive of the folder contents.
  3. Post this archive and description of your issues to the community forum.
UI Expand
titleControl Tower logs
  1. Go to %install_dir%\Workfusion\tomcat\logs (the default path is C:\IntelligentAutomationCloud\Workfusion\tomcat\logs).
  2. Create a ZIP archive of the folder contents.
  3. Post this archive and description of your issues to the community forum.
UI Expand
titleAgent logs
Info

Valid since version 

Status
colourGreen
title2.3.0

  1. Go to %install_dir%\Agent\Logs\ (the default path is C:\IntelligentAutomationCloud\Agent\Logs\).
  2. Create a ZIP archive of the folder contents.
  3. Post this archive and description of your issues to the community forum.